HEAT TRANSFER AT CONDENSATION PUMPING OF HELIUM 3 IN DILUTION REFRIGERATORS.

Author(s) : SOBOLEV V. I.

Type of article: Article

Summary

HEAT TRANSFER WAS STUDIED IN CONDENSATION PUMPS INSTALLED IN A HELIUM 3-HELIUM 4 REFRIGERATOR. THE CALCULATIONS AND EXPERIMENTAL RESULTS SHOW THAT THIS PUMP SYSTEM CAN ENSURE SUFFICIENTLY LARGE CIRCULATIONS OF HELIUM 3. THE CIRCULATION RATE OF ABOUT 250 MICROMOLES AND THE TEMPERATURE ABOUT 12 MILLIK WERE OBTAINED IN THE OPERATING DILUTION REFRIGERATION.

Details

  • Original title: HEAT TRANSFER AT CONDENSATION PUMPING OF HELIUM 3 IN DILUTION REFRIGERATORS.
  • Record ID : 1991-2376
  • Languages: English
  • Source: Fiz. nizk. Temp. - vol. 16 - n. 5
  • Publication date: 1990
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (13)
See the source