Performance characteristics of pulse tube refrigerators.

Author(s) : HUANG B. J., TZENG T. M.

Type of article: Article

Summary

Experiments were carried out to investigate the performance characteristics of pulse-tube refrigerators. The cool-down time is dominated by the time constant of the pulse tube wall and the dynamics approaches that of a first order system. For steady-state operation, the cold-end temperature was found to vary with the time constant of the pulse tube wall and the cooling load increases monotonically with this time constant. The gas conpression-expansion process inside the pulse tube lies between isothermal and adiabatic and the performance of a pulse tube refrigerator at transient and steady states is mainly dominated by the time constant of the pulse-tube wall.

Details

  • Original title: Performance characteristics of pulse tube refrigerators.
  • Record ID : 1994-3339
  • Languages: English
  • Source: Cryogenics - vol. 33 - n. 12
  • Publication date: 1993/12