Performance of high-temperature absorption heat transformers using Alkitrate as the working pair.

Author(s) : ZHUO C. Z., MACHIELSEN C. H. M.

Type of article: Article

Summary

Performance parameters of single-stage, double-lift and triple-lift cycles for 1 megawatt industrial-scale absorption heat transformers are calculated by a computer-simulation model. It is concluded that Alkitrate is especially useful for operating at high temperatures, up to 260 deg C, the COPs of Alkitrate cycles are the same or better than those of water-lithium bromide cycles, under the same operating conditions. However, attention should be paid to the solubility problem of Alkitrate at low temperatures, a condensing temperature of the working fluid (i.e. water) below 50 deg C is not recommended.

Details

  • Original title: Performance of high-temperature absorption heat transformers using Alkitrate as the working pair.
  • Record ID : 1996-2234
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 16 - n. 3
  • Publication date: 1996/03

Links


See other articles in this issue (2)
See the source