Review of stability experiments on cable-in-conduit conductors.

Author(s) : LUE J. W.

Type of article: Article

Summary

By reviewing the stability experiments performed on cable-in-conduit conductors, it is shown that, depending on the effectiveness of the heating induced flow, the effective heat transfer coefficient can be as low as 400 watts/m2.K or as high as 1400 watts/m2.K. Based on the review, conclusions and comments are made with regard to the permissible current density, ramp rate limitation and dual cooling channel in such a conductor.

Details

  • Original title: Review of stability experiments on cable-in-conduit conductors.
  • Record ID : 1996-0033
  • Languages: English
  • Source: Cryogenics - vol. 34 - n. 10
  • Publication date: 1994/10

Links


See other articles in this issue (6)