Summary
Theoretical analysis of multistage thermoelectric cooler was done in this paper. The cooling temperatures of four different multistage thermoelectric coolers were obtained in three different conditions by ANSYS simulation software. A test bench was conducted to verify the simulation. The simulation results showed that the cooling temperature of thermoelectric cooler was influenced by the distance of the thermoelectric couple. and the distance of thermoelectric couple should be considered in designing the cooler. The test results showed that the optimal operating voltage of the thermoelectric cooler was equal to 12V. The refrigeration temperature was extremely influenced by the external environment. The insulation material had an important impact on the performance of multistage thermoelectric cooler. The test results also showed that the input current and power would decrease with the hot end temperature increasing; the largest temperature difference and cooling temperature would increase with the hot end temperature increasing.
Available documents
Format PDF
Pages: 94-99
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30011250
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 35 - n. 156
- Publication date: 2014/04
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2014.02.094
Links
See other articles in this issue (13)
See the source
Indexing
-
Evaluation of thermoacoustic cycles for cooling...
- Author(s) : PAEK I., BRAUN J. E., MONGEAU L.
- Date : 2006/07/17
- Languages : English
- Source: 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
View record
-
Performance analysis of a new thermal managemen...
- Author(s) : YANG J., HAN J., ZHU X., GE Y., ZHU W.
- Date : 2023/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Formats : PDF
View record
-
Climate influence on the operation of refrigera...
- Author(s) : TSOY A. P., TSOY D. A., GRANOVSKY A. S., et al.
- Date : 2015/01
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 1
View record
-
Numerical analysis and optimization of a solar ...
- Author(s) : ZENG D. Q., LI H., DAI Y. J., et al.
- Date : 2014/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 73 - n. 1
View record
-
Linear analysis of acoustic characteristics in ...
- Author(s) : KAWAMOTO A., OZAWA M., ARIKAWA F., KATAOKA M.
- Date : 1996
- Languages : Japanese
- Source: Trans. JAR - vol. 13 - n. 2
View record