IIR document

Thermodynamic performance evaluation of three generations of a magnetic air-conditioning prototype.

Summary

This study presents an experimental evaluation of the thermodynamic performance of three generations of a magnetic air-conditioning prototype. The constraints, operating conditions and design modifications introduced after each prototype generation are identified and discussed in detail. The main motivation for the changes lead ing to the three generations was the availability and reliability of the commercial magnetocaloric material used, which were limited by supply-chain constraints, chemical and mechanical instability, and low manufacturing reproducibility. Dedicated engineering solutions were developed to address these limitations, enabling the ex perimental evaluation of three successive generations of the system. The performance of each generation was assessed using metrics such as cooling capacity, temperature span, coefficient of performance and second-law efficiency, evaluated at both the active magnetic regenerator and system levels. The first prototype established a robust experimental benchmark, delivering the required temperature span for air-conditioning operation under practical conditions. It operated between thermal reservoir temperatures of 22◦C and 35◦C and achieved cooling capacities up to 480W. Advanced thermodynamic analysis further highlighted the high-efficiency potential of magnetic refrigeration at the regenerator level, while demonstrating that losses associated with auxiliary compo nents are the dominant factor limiting system-level performance. Overall, the three prototype versions provide a validated experimental foundation and a clear pathway for future improvements, particularly through targeted optimization of supporting components and their integration with the magnetic cycle.

Available documents

Format PDF

Pages: 15

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Thermodynamic performance evaluation of three generations of a magnetic air-conditioning prototype.
  • Record ID : 30034835
  • Languages: English
  • Subject: Technology
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 187
  • Publication date: 2026/07
  • DOI: http://dx.doi.org/10.1016/j.ijrefrig.2026.106952

Links


See other articles in this issue (35)
See the source