Summary
Reduction in investment of over 100 million euros reduction and more than 5 million euros per annum in operating costs for cooling telecom systems, combined with a higher level of cooling availability and in particular of the telecom technology; these are the consequences of a very special paradigm change in the cooling of telecom systems. The use of the new cooling system will enable Swisscom alone to make savings of around 70 000 MWh in electricity throughout Switzerland, with investments being reduced by more than 100 million euros. The sustainability can also be seen in the drastic reduction in refrigerant quantities and generally lower material flows. However, the solution strategies are not only attractive to other telecom providers but also offer valuable input for future computer centre cooling systems.
Details
- Original title: A 95% more efficient telecom cooling system.
- Record ID : 2008-2712
- Languages: English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
- Publication date: 2007/06/10
Links
See other articles from the proceedings (76)
See the conference proceedings
Indexing
-
Monitoring and benchmarking in Telecom fixed-li...
- Author(s) : CORGNATI S. P., TALÀ N., BEDOGNI F.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Impianti di condizionamento per i nuovi reparti...
- Author(s) : GATTESCHI A.
- Date : 2004/03/03
- Languages : Italian
- Source: Impianti, edifici, città: integrazione e nuove visioni di progetto e di gestione. 44e Convegno Internazionale AICARR [CD-ROM]./ HVAC&R systems, envelope and urban context: integration and new vision of design and operation. 44th International conference of AICARR [CD-ROM].
View record
-
La progettazione del risparmio energetico negli...
- Author(s) : TRECATE R., VIO M.
- Date : 2002/03/07
- Languages : Italian
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
View record
-
Study on efficiency improvement of year-round c...
- Author(s) : UEKUSA T., YANAGI M., WARAGAI S.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record
-
OPTIMAL DESIGN OF AN AIR JET FOR SPOT COOLING.
- Author(s) : HWANG C. L., TILLMAN F. A., LIN M. J.
- Date : 1984
- Languages : English
View record