A simple method to perform measurements near the critical temperature in YBCO samples.

Author(s) : FONTANA F., PERSICO V., VALENTINO M.

Type of article: Article

Summary

A high degree of thermal stability of the sample at any desired temperature near critical temperature is achieved using a pressurized bath of liquid argon in a close cryostat. Examples of measurements performed by such a technique are presented.

Details

  • Original title: A simple method to perform measurements near the critical temperature in YBCO samples.
  • Record ID : 1995-2755
  • Languages: English
  • Source: Rev. sci. Instrum. - vol. 65 - n. 8
  • Publication date: 1994/08
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (1)
See the source