AIR-AIR HEAT PUMPS UNDER THE WINDOW.

[In German. / En allemand.]

Author(s) : UBERALL P.

Type of article: Article

Summary

ILLUSTRATES A 77 CM HIGH, 35 CM WIDE AND 60 CM DEEP, BENEATH THE WINDOW, DECENTRALISED, AIR-AIR HEAT PUMP. THE INSTALLATION HAS BEEN IN OPERATION IN A NEW, TWO FAMILY HOUSE IN STUTTGART-BOTNANG. WARM EXHAUST AIR PLUS OUTDOOR AIR IS DRAWN ACROSS THE CONDENSER AND THE COOLED AIR IS EXHAUSTED THROUGH A SLOT IN THE HOUSE FACADE. THE CONDENSER GIVES UP THE RECOVERED HEAT TO COOL AIR DRAWN IN FROM THE FLOOR AREA WHICH IS THEN WARMED AND IF REQUIRED, FILTERED AND HUMIDIFIED BEFORE BEING RETURNED TO THE ROOM. GIVES DETAILS OF THE HOUSE, ELECTRICITY CONSUMPTION, ECONOMICS AND OVERALL COSTS. NOTES ITS SUITABILITY FOR MODERNISING BUILDINGS. (INT. BUILD. SERV. ABSTR. , GB., 19, N.2, 1984, 12-13, 84-00446.

Details

  • Original title: [In German. / En allemand.]
  • Record ID : 1984-2424
  • Languages: German
  • Source: Elektrowärme int., A - n. 6
  • Publication date: 1983
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source