AN AUTOMATIC LIQUID NITROGEN FILLING SYSTEM.

Author(s) : MONAGHAN C. P., O'BRIEN E. J. Jr

Type of article: Article

Summary

A SYSTEM IS DESCRIBED WHICH AUTOMATICALLY REFILLS A RESEARCH DEWAR FROM A RESERVOIR DEWAR. TWO SENSORS ARE USED FOR DETECTING THE LIQUID NITROGEN LEVEL IN THE RESEARCH DEWAR, AND AN EXTERNAL NITROGEN GAS SUPPLY IS USED TO PROVIDE THE PRESSURE TO EFFECT THE TRANSFER OF LIQUID NITROGEN.

Details

  • Original title: AN AUTOMATIC LIQUID NITROGEN FILLING SYSTEM.
  • Record ID : 1982-0708
  • Languages: English
  • Source: Cryogenics - vol. 21 - n. 9
  • Publication date: 1981

Links


See other articles in this issue (4)