OPTIMAL THERMAL DESIGN OF HELIUM DEWAR WITH LIQUID NITROGEN AND VAPORIZED HELIUM COOLED INTERCEPTS.
Author(s) : LI Q.
Type of article: Article
Summary
AN OPTIMAL THERMAL DESIGN METHOD FOR HELIUM DEWARS WITH LIQUID NITROGEN AND VAPORIZED HELIUM COOLED HEAT INTERCEPTS IS PRESENTED. THE METHOD MINIMIZES TOTAL REFRIGERATION POWER REQUIRED FOR THE NITROGEN AND HELIUM LIQUEFIERS BY OPTIMIZING THE LIQUID NITROGEN AND VAPORIZED HELIUM COOLED INTERCEPTS BOTH IN SUPERINSULATION AND ON SUPPORTS. RESULTS ARE CALCULATED FOR SUPERINSULATED HELIUM DEWARS WITH STAINLESS STEEL AISI 304 AND EPOXY-FIBERGLASS G-10CR SUPPORTS, RESPECTIVELY.
Details
- Original title: OPTIMAL THERMAL DESIGN OF HELIUM DEWAR WITH LIQUID NITROGEN AND VAPORIZED HELIUM COOLED INTERCEPTS.
- Record ID : 1991-1923
- Languages: English
- Source: Adv. cryog. Eng. - vol. 35 A
- Publication date: 1990
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (47)
See the source
Indexing
-
DEVICE FOR EMPTYING LIQUID NITROGEN DEWARS.
- Author(s) : MILLER W. M, TERRIS B. D., GINSBERG D. M.
- Date : 1981
- Languages : English
- Source: Rev. sci. Instrum. - vol. 52 - n. 4
View record
-
AN AUTOMATIC LIQUID NITROGEN FILLING SYSTEM.
- Author(s) : MONAGHAN C. P., O'BRIEN E. J. Jr
- Date : 1981
- Languages : English
- Source: Cryogenics - vol. 21 - n. 9
View record
-
PASSIVE LEVEL INDICATOR AND VALVE FOR TRANSFERR...
- Author(s) : GOODRICH R. G.
- Date : 1984
- Languages : English
- Source: Rev. sci. Instrum. - vol. 55 - n. 7
View record
-
SELF-PRESSURIZING LIQUID-NITROGEN FILLER.
- Author(s) : CHUMBLEY P. E., HULSE M. M.
- Date : 1985/07
- Languages : English
- Source: Rev. sci. Instrum. - vol. 56 - n. 7
View record
-
Design changes in the sample mount and temperat...
- Author(s) : BOUCHALKHA A., WICKSTED J. P., SHIELDS P.
- Date : 1993/08
- Languages : English
- Source: Rev. sci. Instrum. - vol. 64 - n. 8
View record