Analysis on hollow fibre membrane heat exchanger applying to the lithium bromide absorption refrigeration system.

Intercambiador de calor con membrana de fibra hueca: análisis sobre la aplicación a un sistema de refrigeración de absorción con bromuro de litio.

Author(s) : WANG Z., FENG S., LI Y., et al.

Type of article: Article

Summary

This article is the Spanish translation of an article presented at the 12th International Refrigeration and Air Conditioning Conference, Purdue University, USA (see the Bulletin of the IIR, reference 2009-1561). The aim of this work is to bring forward a new style heat exchanger about hollow fibre membrane module, and to analyze the performance which can expectantly be applied in the lithium bromide absorption refrigeration system. Polyvinylidene fluoride hollow fibre membrane module was adopted as the new style solution heat exchanger, hot feed solution from the generator flowed into the lumen side of membranes while cold feed solution from the absorber flowed away the shell side. Heat transfer and water vapour mass transfer occurred simultaneously in the membrane module, only water vapour can diffuse across the membrane pore from one side to the other side according to the water vapour pressure difference between the both sides of the membrane. Mathematical equations of distributed parameter for heat transfer and mass transfer process in membrane heat exchanger was built, parameters of solution heat exchanger for traditional 10 kW cooling capacity absorption refrigeration system was adopted as the simulation parameters, and the parallel-flow process and the counter-flow process was compared by numerical simulation. The simulation result shows that the counter-flow process was the better flow mode because the mean temperature difference was larger and the mass transfer process were more steadily from the lumen side to the shell side. The heat caused by mass transfer may be one third of the total heat transfer.

Available documents

Format PDF

Pages: pp. 32-40 (7 p.)

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Intercambiador de calor con membrana de fibra hueca: análisis sobre la aplicación a un sistema de refrigeración de absorción con bromuro de litio.
  • Record ID : 2010-0440
  • Languages: Spanish
  • Source: Frío Calor Aire acondicionado - vol. 37 - n. 414
  • Publication date: 2009/05

Links


See other articles in this issue (3)
See the source