APPLY DEPRESSURING ANALYSIS TO CRYOGENIC PLANT SAFETY.

Author(s) : CHIU C. H.

Type of article: Article

Summary

IN THE EVENT OF FIRE, PRESSURE VESSELS ARE WEAKENED AND LIQUIDS CONTAINED WITHIN THEM ARE VAPOURISED WITH RISING PRESSURES. DEPRESSURISING VALVES MUST PASS A VARIABLE FLOW RATE AT A CHANGING PRESSURE DIFFERENCE TO DROP THE VESSEL PRESSURE TO A SAFE LEVEL. THE PROBLEM IS COMPLICATED WHEN THE CONTENTS ARE MIXTURES OF TWO CONSTITUENTS OF DIFFERENT VOLATILITY. METHODS OF NUMERICAL AND ANALYTICAL APPROACH ARE DESCRIBED AND A NUMERICAL EXAMPLE IS SHOWN. D.W.H.

Details

  • Original title: APPLY DEPRESSURING ANALYSIS TO CRYOGENIC PLANT SAFETY.
  • Record ID : 1983-1237
  • Languages: English
  • Source: Hydrocarbon Processing - vol. 61 - n. 11
  • Publication date: 1982
  • Document available for consultation in the library of the IIR headquarters only.