CARRYING OUT INSULATION WORK ON A REFRIGERATED TRUCK.
Author(s) : BRADFORD A.
Type of article: Article
Summary
THE ARTICLE CONCERNS MAINLY A SUGGESTED METHOD OF CALCULATION FOR THE SIZE OF REFRIGERATION UNIT TO BE USED FOR A SPECIFIC EXAMPLE. SOME INTERESTING POINTS ARE RAISED CONCERNING ALLOWANCES FOR SOLAR GAIN, AIR CHANGES, ETC. D.W.H.
Details
- Original title: CARRYING OUT INSULATION WORK ON A REFRIGERATED TRUCK.
- Record ID : 1984-1675
- Languages: English
- Publication date: 1984/01
- Source: Source: Refrig. Air Cond. Heat Recov.
vol. 87; n. 1030; 48-51; 3 fig.; 1 tabl. - Document available for consultation in the library of the IIR headquarters only.