Characterization of evaporator scale of Indian sugar industry.
Author(s) : SRIVASTAVA D., MOHANTY B., BHARGAVA R.
Type of article: Article
Summary
Fouling in Multiple Effect Evaporator (MEE) systems is the major unresolved problem encountered in most of the chemical process industries. In order to mitigate fouling from MEE system used in the cane sugar industry, it is necessary to understand the type and nature of foulant present in it. In the current paper, the authors have tried to present the detailed analysis of deposits present in each effect of a quadruple effect MEE system used in Indian sugar industry. For this purpose, various instrumental analyses were performed and different organic and inorganic compounds and elements present in the deposits were identified. Further, it has also been observed that some elements show a particular trend of deposition from first effect to last effect. This analysis will help industry to select particular mitigation techniques to clean deposits.
Details
- Original title: Characterization of evaporator scale of Indian sugar industry.
- Record ID : 30017624
- Languages: English
- Source: Applied Thermal Engineering - vol. 98
- Publication date: 2016/04/05
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2015.12.130
Links
See other articles in this issue (61)
See the source
Indexing
- Themes: Evaporators, condensers and other heat exchangers
- Keywords: Sugar cane; Industrial application; India; Evaporator; Fouling
-
Monitoring and assessment of an industrial anti...
- Author(s) : RUBIO D., LĂ“PEZ-GALINDO C., CASANUEVA J. F., et al.
- Date : 2014/06
- Languages : English
- Source: Applied Thermal Engineering - vol. 67 - n. 1-2
View record
-
SYSTEME AUTOMATIQUE DE NETTOYAGE EN CONTINU POU...
- Date : 1987/08
- Languages : French
View record
-
Gas-side fouling, erosion and corrosion of heat...
- Author(s) : LI M. J., TANG S. Z., ZHAO F. I., et al.
- Date : 2017/11/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 126
View record
-
Optimal design of tests for heat exchanger foul...
- Author(s) : PALMER K. A., HALE W. T., SUCH K. D., et al.
- Date : 2016/02/25
- Languages : English
- Source: Applied Thermal Engineering - vol. 95
View record
-
Air-side fouling of finned heat exchangers: Par...
- Author(s) : INAMDAR H. V., GROLL E. A., WEIBEL J. A., GARIMELLA S. V.
- Date : 2023/07
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 151
- Formats : PDF
View record