DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP3.

Author(s) : LEE R., DEVOTTA S., HOLLAND F. A.

Type of article: Article

Summary

THE THEORETICAL RANKINE POWER CYCLE EFFICIENCIES AND THE PRESSURE RATIOS HAVE BEEN PRESENTED FOR RANKINE POWER CYCLES OPERATING ON PP3 (PERFLUORO 1,3 DIMETHYLCYCLOHEXANE -C8 F16 ). THESE VALUES ARE LISTED IN TABULAR FORM FOR TEMPERATURE DROPS OF 10-75 K AND FOR BOILER TEMPERATURES 338-493 K (65-220 DEG C) IN 5 K INCREMENTS. A COMPOSITE GRAPH ILLUSTRATES THE FEASIBLE OPERATING RANGE FOR PP3 POWER CYCLE SYSTEMS.

Details

  • Original title: DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP3.
  • Record ID : 1984-2222
  • Languages: English
  • Source: J. Heat Recov. Syst. - vol. 3 - n. 6 1983
  • Publication date: 1983