IIR document

DETERMINATION OF OPTIMUM REFRIGERANT CHARGE FOR DOMESTIC REFRIGERATOR UNITS.

Author(s) : DMITRIYEV V. I., PISARENKO V. E.

Type of article: Article, IJR article

Summary

A METHOD IS GIVEN OF ASSESSING THE OPTIMUM REFRIGERANT (R12) CHARGE FOR DOMESTIC REFRIGERATORS EMPLOYING A CAPILLARY TUBE EXPANSION DEVICE. THIS AMOUNT OF REFRIGERANT WAS FOUND TO DEPEND MAINLY ON THE VOLUME OF THE EVAPORATOR AND CONDENSER. MEASUREMENTS WERE MADE WITH DIFFERENT CHARGES AND IT WAS CONCLUDED THAT AMBIENT AIR TEMPERATURE IS NOT A SIGNIFICANT FACTOR AND THAT COP IS MORE SENSITIVE TO OVERFILLING THAN UNDERFILLING. A 10% EXCESS OF REFRIGERANT REDUCED THE COP BY 6-12%, WHEREAS A SIMILAR DEFICIENCY OF REFRIGERANT REDUCED THE COP BY ONLY 4-6%. EQUATIONS AND DIAGRAMS ARE GIVEN ENABLING THE OPTIMUM CHARGE TO BE ESTIMATED FOR REFRIGERATION UNITS HAVING INTERIOR VOLUMES OF 120 TO 180 DM3 AND WITH VOLUMETRIC CAPACITIES OF CONDENSER AND EVAPORATOR IN THE RANGE 90-160 CM3.

Available documents

Format PDF

Pages: 178-180

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: DETERMINATION OF OPTIMUM REFRIGERANT CHARGE FOR DOMESTIC REFRIGERATOR UNITS.
  • Record ID : 1985-0578
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 7 - n. 3
  • Publication date: 1984

Links


See other articles in this issue (9)