Effects of a non-equilibrium two-phase refrigerant flow at subcooled temperatures on the performance of an R-600a refrigeration system.

Author(s) : KO J., JEONG J. H.

Type of article: Article, IJR article

Summary

Previous researches reported the observation of a thermodynamic non-equilibrium two-phase refrigerant between the condenser outlet and the expansion device inlet under a subcooled condition, where the fluid temperature is below the corresponding saturation temperature. Experiments are conducted to examine the influence of the non-equilibrium subcooled two-phase state of R-600a on the performance of a refrigeration system. The enthalpy of the non-equilibrium state of the refrigerant is calculated using three different methods, and the heat rejection from the condenser and the coefficient of performance (COP) of the refrigeration system are evaluated. Compared to a case in which the refrigerant flows in an equilibrium subcooled state, the condenser heat rejection and the COP both decrease when the refrigerant is in a non-equilibrium subcooled two-phase state.

Available documents

Format PDF

Pages: 118-130

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Effects of a non-equilibrium two-phase refrigerant flow at subcooled temperatures on the performance of an R-600a refrigeration system.
  • Record ID : 30023886
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 87
  • Publication date: 2018/03
  • DOI: http://dx.doi.org/10.1016/j.ijrefrig.2017.10.029