Experimental analysis of the multi-bypass principle in pulse tube refrigerators.

Author(s) : CAI J. H., WANG J. J., ZHU W. X., ZHOU Y.

Type of article: Article

Summary

The paper describes the structural characteristics and the mechanical performance of a co-axial pulse tube refrigerator with a multi-bypass. Some experimental results and an experimental analysis of the multi-bypass method are also given. The minimum attainable temperature at the cold end of a co-axial pulse tube refrigerator with multi-bypass is 33 K at a vacuum of 10 millitorr. This shows that the performance of a pulse tube refrigerator is comparable to that of a Stirling refrigerator. Moreover, pulse tube systems would probably be more extensively used than Stirling refrigerators beause of their advantages in terms of structural simplicity and mechanical reliability.

Details

  • Original title: Experimental analysis of the multi-bypass principle in pulse tube refrigerators.
  • Record ID : 1996-0009
  • Languages: English
  • Source: Cryogenics - vol. 34 - n. 9
  • Publication date: 1994/09

Links


See other articles in this issue (4)
See the source