IIR document

Experimental research on the refrigeration performance of thermoelectric-refrigerating unit.

Author(s) : WANG T., OUYANG X. P., XUE N.

Summary

This paper develops a refrigeration system containing thermoelectric-refrigerating unit, which is mainly used for blood preserving. By controlling the working voltage, ambient temperature and exterior condition for heat dissipation, the main factors which influence the refrigeration performance of the thermoelectric-refrigerating unit have been found and the best working parameters such as the optimal working voltage, the optimal working current, the optimal heat dissipation system were determined. Consequently the minimum temperature of the thermoelectric-refrigerating unit was obtained through experiments under the different conditions with different ambient temperature(variable) and the best working parameters (variables).

Available documents

Format PDF

Pages: ICR07-B2-903

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental research on the refrigeration performance of thermoelectric-refrigerating unit.
  • Record ID : 2007-2620
  • Languages: English
  • Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Publication date: 2007/08/21