Thermodynamics assessment of desiccant systems with targeted and relaxed humidity control schemes.
Author(s) : JALALZADEH-FAZAR A. A., HODGE B. K., STEELE W. G.
Summary
The performance of desiccant systems for applications requiring stringent control of humidity under varying load conditions is evaluated in this paper. The analyses are performed using a program for a commercially available gas-fired desiccant system. The program predicts the properties of the supply air once the operating conditions are specified. Two scenarios are addressed with respect to the flexibility in humidity control. The first, labeled "targeted" control, pertains to maintaining the humidity level of supply air at a set point within a reasonable control band. The second approach is more flexible in that the controlled variable can assume any value below the set point.
Details
- Original title: Thermodynamics assessment of desiccant systems with targeted and relaxed humidity control schemes.
- Record ID : 1999-3813
- Languages: English
- Source: ASHRAE Transactions. 1998 annual Meeting, Toronto, Ontario + CD-ROM.
- Publication date: 1998
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (39)
See the conference proceedings
-
Control of temperature and humidity by wet outd...
- Author(s) : TATEIWA K.
- Date : 2015/11
- Languages : Japanese
- Source: SHASE - vol. 89 n. 11 - vol. 89 n. 11
View record
-
Development of a novel desiccant chiller with r...
- Author(s) : DAI Y. J., LA D., LI H., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Desiccant HVAC systems for commercial buildings.
- Author(s) : MAZZEI P., MINICHIELLO F., PALMA D.
- Date : 2002/04
- Languages : English
- Source: Applied Thermal Engineering - vol. 22 - n. 5
View record
-
Performance of a four-divided adsorbent rotor f...
- Author(s) : KODAMA A., SANNO A., OSAKA Y.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Effect of regeneration temperatures in the exer...
- Author(s) : ENTERIA N., YOSHINO H., TAKAKI R., et al.
- Date : 2013/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 8
- Formats : PDF