Summary
Air conditioning systems are usually operated under part load conditions, and segmented handling air-conditioning system has significant advantages of realizing energy-saving operation under part load conditions. Chillers in serial configuration was carried out on a test bed of segmented handling air-conditioning system, and the performance of system in different load conditions were studied. Experiment results show that: the maximum load that segmented handling air-conditioning system can handle is only 81.5% compared with conventional systems when the design load is the same. When the load reduces from 81.5% to 50%, the chillers of the system average COP increases from 3.13 to 4.16, which indicates that segmented handling air conditioning system can create a big energy saving potential under part load conditions.
Available documents
Format PDF
Pages: 25-29, 48
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30019767
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 35 - n. 159
- Publication date: 2014/10
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2014.05.25
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Air conditioner; Chiller; Performance; Expérimentation; Part load
-
Evaluation of air-conditioning and water heatin...
- Author(s) : KAWANO M., AKAHANE H., KUMAGAI M., et al.
- Date : 2011/04
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 169
View record
-
Modulation method of scroll compressor based on...
- Author(s) : WANG B., HAN L., SHI W., et al.
- Date : 2012/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 37
View record
-
Design and test of split evaporative air condit...
- Author(s) : LIANG C., SUN Z., LIU J.
- Date : 2014/10
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 35 - n. 159
- Formats : PDF
View record
-
Distribution performance assessment and structu...
- Author(s) : YANG G., WENG X., DING G., et al.
- Date : 2016/04
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 37 - n. 168
- Formats : PDF
View record
-
New method for calculating cooling load of elec...
- Author(s) : SHI J., WANG L., TAN J.
- Date : 2013/08
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 280
- Formats : PDF
View record