High pressure cell for solid helium 3 using Stycast 1264.

Author(s) : TSUJII H., IKEYA A., NOZAWA M., INOUE S., MAMIYA T.

Type of article: Article

Summary

In the measurements of the magnetic susceptibility of solid helium 3, a sample cell must withstand pressures up to 20 megapascals and it must be made from nonmetallic materials to allow the alternating-current magnetic field to penetrate into the sample. The cell which was made from Stycast 1264 withstood 25 megapascals.

Details

  • Original title: High pressure cell for solid helium 3 using Stycast 1264.
  • Record ID : 1996-2100
  • Languages: English
  • Source: Rev. sci. Instrum. - vol. 66 - n. 9
  • Publication date: 1995/09
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source