Summary
In the measurements of the magnetic susceptibility of solid helium 3, a sample cell must withstand pressures up to 20 megapascals and it must be made from nonmetallic materials to allow the alternating-current magnetic field to penetrate into the sample. The cell which was made from Stycast 1264 withstood 25 megapascals.
Details
- Original title: High pressure cell for solid helium 3 using Stycast 1264.
- Record ID : 1996-2100
- Languages: English
- Source: Rev. sci. Instrum. - vol. 66 - n. 9
- Publication date: 1995/09
- Document available for consultation in the library of the IIR headquarters only.