Investigation of synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler.
Author(s) : ARABLU M., JAFARIAN A.
Type of article: Article
Summary
In this paper synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler (SPTC) have been considered. In this respect, a finite volume code was developed to simulate the SPTC. Set of governing equations were written in a general form such that all porous and non-porous sections of the system could be modeled. Results showed that synchronous application of double inlet and multi-mesh regenerator optimizes the phase shift between velocity and pressure at the warm end of the pulse tube, increases the regenerator’s outlet pressure amplitude, decreases inertial and viscous losses in the hot end of the regenerator and consequently increases the COP of the system. Furthermore, it was observed that a minimum temperature of 60.3 K and COP of 0.03996 @ 80 K is attainable using optimum multi-mesh regenerator and double inlet; whereas, for a simple SPTC with a uniform mesh regenerator, a minimum temperature of 71.3 K and maximum COP of 0.0227 @ 80 K are concluded.
Details
- Original title: Investigation of synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler.
- Record ID : 30007941
- Languages: English
- Source: Cryogenics - vol. 54
- Publication date: 2013/02
- DOI: http://dx.doi.org/10.1016/j.cryogenics.2012.09.008
Links
See other articles in this issue (5)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Pulse tube; Regenerator; Simulation; Performance; Cryocooler
-
Untersuchungen zum Leistungsverhalten eines zwe...
- Author(s) : PAN H., HOFMANN A., OELLRICH L.
- Date : 1999/11/17
- Languages : German
- Source: DKV-Tagungsbericht 26. 1999, Berlin.
View record
-
Analytical treatment of counterflow pulse-tube ...
- Author(s) : WILL M. E., WAELE A. T. A. M. de
- Date : 2006/06
- Languages : English
- Source: Cryogenics - vol. 46 - n. 6
View record
-
Effects of the inertance tube length and diamet...
- Author(s) : FAROUK B., ANTAO D.S.
- Date : 2012/09/11
- Languages : English
- Source: Cryogenics 2012. Proceedings of the 12th IIR International Conference: Dresden, Germany, September 11-14, 2012.
- Formats : PDF
View record
-
Fundament of input power distribution and phase...
- Author(s) : ZHU S., LIN Y.
- Date : 2020/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Formats : PDF
View record
-
Pulse tube refrigerators.
- Author(s) : MATSUBARA Y.
- Date : 1994
- Languages : Japanese
- Source: Trans. JAR - vol. 11 - n. 2
View record