Investigation on solar hybrid desiccant cooling system for commercial premises with high latent cooling load in subtropical Hong Kong.
Author(s) : FONG K. F., LEE C. K., CHOW T. T., et al.
Type of article: Article
Summary
This study found that the solar hybrid desiccant cooling system (SHDCS) was more effective to handle the premises with high latent cooling load in the hot and humid climate compared to the conventional airconditioning system. The SHDCS was designed to use the solar-thermal desiccant cooling to tackle the latent load; and the electrical vapour compression refrigeration to cater the sensible load. In this study, the typical commercial premises with high latent load were the Chinese restaurant and the wet market. The effectiveness of SHDCS included both better indoor cooling performance and higher year-round energy-saving potential. The annual primary energy consumption of SHDCS could be lower than that of the conventional system by 49.5% in the Chinese restaurant and 13.3% in the wet market. For the premises with more stringent temperature and humidity requirements, like the Chinese restaurant, the contribution of SHDCS in energy saving would be significant. Utilization of solar energy could ensure the energy-saving potential of SHDCS for the premises with high latent load. As a whole, the study assures the wider application of solar air-conditioning in the subtropical Hong Kong.
Details
- Original title: Investigation on solar hybrid desiccant cooling system for commercial premises with high latent cooling load in subtropical Hong Kong.
- Record ID : 30005333
- Languages: English
- Source: Applied Thermal Engineering - vol. 31 - n. 16
- Publication date: 2011/11
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2011.06.024
Links
See other articles in this issue (19)
See the source
-
Performance enhancement of a desiccant evaporat...
- Author(s) : ELGENDY E., MOSTAFA A., FATOUH M.
- Date : 2015/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 51
- Formats : PDF
View record
-
Des résultats prometteurs pour le rafraîchissem...
- Author(s) : LABED N., JOUBERT P., BURLOT M.
- Date : 2018/03
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - n.1168
View record
-
Potential study of desiccant wheel-based water ...
- Author(s) : GLÜCK C., ROLDAN BLASCO E., LENZ B., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Effect of operation conditions on the second la...
- Author(s) : UCKAN I., YILMAZ T., BUYUKALACA O.
- Date : 2017/02/25
- Languages : English
- Source: Applied Thermal Engineering - vol. 113
View record
-
Planung und Wirtscheftlichkeit von DEC-Anlagen ...
- Author(s) : MAI R.
- Date : 2013/06
- Languages : German
- Source: KI Kälte Luft Klimatechnik - n. 6-7
View record