Local heat transfer coefficients for a flush-mounted glazing unit.

Summary

The paper presents an attempt to extract local, indoor insulating glazing unit (IGU) heat transfer coefficients based directly on indoor IGU surface temperature measurements. Determination of a local heat transfer coefficient profile for window assemblies is needed to study local phenomena such as condensation. The use of non-isothermal surface thermographic temperatures is another distinguishing feature of the work.

Details

  • Original title: Local heat transfer coefficients for a flush-mounted glazing unit.
  • Record ID : 1999-3074
  • Languages: English
  • Source: ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.
  • Publication date: 1998