Location of condensing units of split-type air conditioners in low-rise residences.
Author(s) : CHOW T. T., LIN Z., YANG Y.
Type of article: Article
Summary
This is a second paper on the use of air conditioning plant rooms to house the condensing units of split-type air conditioners in residences. Numerical analysis of the airflow and heat dissipation at condensing unit level in a low-rise residence in Hong Kong is presented. The energy performances of the air conditioners as well as the levels of thermal comfort in the outside vicinity for the proposed options were evaluated. The findings of this article give good guidance to the location of split-type air conditioners in future low-rise residence projects.
Details
- Original title: Location of condensing units of split-type air conditioners in low-rise residences.
- Record ID : 2003-0985
- Languages: English
- Source: Applied Thermal Engineering - vol. 22 - n. 13
- Publication date: 2002/09
Links
See other articles in this issue (4)
See the source
Indexing
-
L'installazione e la manutenzione degli impiant...
- Author(s) : GRICINI E.
- Date : 2002
- Languages : Italian
- Source: Industria & Formazione - vol. 26 - n. 258
View record
-
Applying CFD simulation in analysing split-type...
- Author(s) : CHOW T. T., LIN Z., et al.
- Date : 2000/09
- Languages : English
- Source: Archit. Sci. Rev. - vol. 43 - n. 3
View record
-
Radiant heating and cooling systems. 2.
- Author(s) : KIM K. W., OLESEN B. W.
- Date : 2015/03
- Languages : English
- Source: ASHRAE Journal - vol. 57 - n. 3
View record
-
L'installazione e la manutenzione degli impiant...
- Author(s) : GRICINI E.
- Date : 2007
- Languages : Italian
- Source: Industria & Formazione - vol. 31 - n. 3
- Formats : PDF
View record
-
Influence of air environment parameters and cha...
- Author(s) : CHILENKO V. I., PIMKOV A. L., VERCHININ V. S., et al.
- Date : 2000
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 11
View record