Measurements in buoyancy-opposing laminar flow over a vertical forward-facing step.

Author(s) : ABU-MULAWEH H. I., ARMALY B. F., CHEN T. S.

Type of article: Article

Summary

The results reveal that the buoyancy-opposing force due to the downstream wall heating affects significantly the velocity and temperature distributions, the local Nusselt number, and the location and the size of the recirculation region downstream of the step.

Details

  • Original title: Measurements in buoyancy-opposing laminar flow over a vertical forward-facing step.
  • Record ID : 1997-0154
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 39 - n. 9
  • Publication date: 1996/06