MODIFICATION OF A SIMPLIFIED EQUATION OF STATE FOR R12 REFRIGERANT VAPOUR.

[In Czech. / En tchèque.]

Author(s) : PAZDERA V.

Type of article: Article

Summary

CALCULATION OF SPECIFIC VOLUME (MASS) OF SATURATED AND SUPERHEATED REFRIGERANT VAPOUR FROM THE EQUATION OF STATE FOR REFRIGERANT VAPOUR AT A GIVEN PRESSURE AND TEMPERATURE USING A MINICOMPUTER IS TEDIOUS AND TIME CONSUMING. A SIMPLIFIED EQUATION OF STATE IS GIVEN, SUITABLE FOR R12 REFRIGERANT IN THE SATURATED VAPOUR RANGE FROM 173 TO 313 K (-100 TO 40 DEG C) WITH AN ERROR LESS THAN 1%, TYPICAL FOR CONVENTIONAL REFRIGERATING AND FREEZING CIRCUITS, BUT LESS SUITABLE FOR AIR CONDITIONING AND HEAT PUMP SYSTEMS. FOR THE TWO LATTER APPLICATIONS A CORRECTION CALCULATION PROCEDURE IS SUGGESTED.

Details

  • Original title: [In Czech. / En tchèque.]
  • Record ID : 1986-1371
  • Languages: Czech
  • Source: Prum. Potravin - vol. 36 - n. 11
  • Publication date: 1985