Summary
For the majority of archive repositories, storing as they do paper type material, environmental conditions of 60 more or less 5% and 15.5 more or less 2.5 °C are recommended by British Standard 5454. Convention tells us that controlling moisture to this close tolerance requires full air conditioning. However, building materials have the ability to absorb moisture during times of excess, retain it and then emit it at times of deficiency. To use these properties with enough accuracy, a tool is needed. The paper describes the development of such a tool by Ove Arup and Partners together with its first application on the design of the new Jersey Archive Centre. The result is a building that aims to achieve the recommended environmental conditions without air conditioning or mechanical ventilation.
Details
- Original title: Passive control of relative humidity to more or less 5%.
- Record ID : 2000-2108
- Languages: English
- Source: CIBSE National Conference 1997. Proceedings.
- Publication date: 1997/10/05
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (34)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Building; Design; Control (automatic); Paper; Material; Hygrometry; Relative humidity; Case study; Air conditioning
-
THE EFFECTS OF RELATIVE HUMIDITY AND TEMPERATUR...
- Author(s) : TROJANOWSKI T. J., WOJCISZYN K.
- Date : 1987/08/24
- Languages : English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
A HUMIDITY DETECTION METHOD FOR USE WITH A ROOM...
- Author(s) : KUWAHARA E.
- Date : 1985
- Languages : English
View record
-
Units for 4-pipe systems for simultaneous produ...
- Author(s) : ROSSI L. de, BUSNARDO E.
- Date : 2011/04/05
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
COMPARISON OF TWO CONTROL STRATEGIES TO SIMULAT...
- Author(s) : HOWELL R. H., GANESH R., SAUER H. J. Jr
- Date : 1987
- Languages : English
View record
-
DYNAMIC CONTROL: FUNDAMENTALS AND CONSIDERATIONS.
- Author(s) : HARTMAN T. B.
- Date : 1988
- Languages : English
View record