Performance of hybrid refrigeration system using ammonia.
Author(s) : LYCHNOS G., TAMAINOT-TELTO Z.
Type of article: Article
Summary
This paper investigates the performance of a hybrid refrigeration system that combines sorption–conventional vapour compression refrigeration machine driven by dual source (heat and/or electricity). The dual source makes the system highly flexible and energy efficient. The ammonia refrigerant (R717) is used in both adsorption and associated conventional refrigeration cycles. The model of thermal compressor corresponds to a multiple pair of compact adsorption generators operating out of phase with both heat and mass recovery for continuous cooling production and better efficiency. Each generator is based on a plate heat exchanger concept using the activated carbon–ammonia pair. The model of conventional vapour compressor is a reciprocating compressor from Frigopol. The hybrid refrigeration performances are presented mainly for ice making and air conditioning applications (TC = 40°C, -5°C < TE < 20°C). The exhaust temperature of the compressor (driving temperature for thermal compressor) varies from 90°C to 250°C. The results show a cooling production ranging from 4 kW to 12 kW with back-up mode (both cycles not operating simultaneously) and from 8 kW to 24 kW with complementary mode (both cycles operating simultaneously). The effective overall COP based on the total equivalent heat rate input varies from 0.24 to 0.76.
Details
- Original title: Performance of hybrid refrigeration system using ammonia.
- Record ID : 30010277
- Languages: English
- Source: Applied Thermal Engineering - vol. 62 - n. 2
- Publication date: 2014/01
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.10.013
Links
See other articles in this issue (15)
See the source
Indexing
-
Themes:
Compression systems;
Ammonia;
Absorption and adsorption systems - Keywords: Ammonia; Adsorption; Compression system; Performance
-
Performance studies on mechanical + adsorption ...
- Author(s) : BANKER N. D., DUTTA P., PRASAD M., et al.
- Date : 2008/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 8
- Formats : PDF
View record
-
Az adszorpciós kompresszor: egy új termoninamik...
- Author(s) : TOTH A.
- Date : 1996
- Languages : Hungarian
- Source: Energiagazdalkodas - vol. 37 - n. 8
View record
-
Ammonia-water two-stage thermal transformers.
- Author(s) : MOROZÛK L. I., MOROZÛK T. V.
- Date : 2000
- Languages : Russian
- Source: Vestnik Mezdunarodarnoj Akademii Holoda - n. 1
View record
-
Cooling performance and energy saving of a comp...
- Author(s) : KAIROUANI L., NEHDI E.
- Date : 2006/02
- Languages : English
- Source: Applied Thermal Engineering - vol. 26 - n. 2-3
View record
-
Performance characteristics of absorption hybri...
- Author(s) : IYOKI S., KOTANI Y., UEMURA T.
- Date : 2000
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 17 - n. 3
View record