PERFORMANCE OF THE PNEUMATICALLY OPERATED GIFFORD-MCMAHON CRYOREFRIGERATOR.

Author(s) : PARMAR P. H., NARAYANKHEDKAR K. G.

Type of article: Article

Summary

THIS PAPER PRESENTS PERFORMANCE OF THE PNEUMATICALLY OPERATED GIFFORD-MCMAHON CRYOREFRIGERATOR. REGENERATOR IS ONE OF THE MOST IMPORTANT COMPONENTS OF THE CRYOREFRIGERATOR WHICH INFLUENCES THE PERFORMANCE OF THE UNIT. THE VALVE MECHANISM SHOULD ALSO SATISFY THE REQUIREMENTS OF THE CYCLE OF OPERATION. USE OF THE PNEUMATICALLY OPERATED VALVE BLOCK MAKES THE UNIT COMPACT. A NO LOAD TEMPERATURE OF 140 K HAS BEEN OBTAINED USING COMPRESSED AIR AT 810 KILOPASCAL.

Details

  • Original title: PERFORMANCE OF THE PNEUMATICALLY OPERATED GIFFORD-MCMAHON CRYOREFRIGERATOR.
  • Record ID : 1985-0002
  • Languages: English
  • Source: Indian J. Cryog. - vol. 8 - n. 1
  • Publication date: 1983
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (8)
See the source