QUENCH DETECTION SYSTEM OF THE EURATOM COIL FOR THE LARGE COIL TASK (LCT).
Author(s) : NOTHER G.
Type of article: Article
Summary
THE SYSTEM IS BASED ON A BRIDGE CIRCUIT WHICH USES A SPECIAL < TWO IN HAND > WINDING TECHNIQUE FOR THE PANCAKES OF THE EUR LCT COIL. THE ELECTRONIC CIRCUIT WAS DESIGNED IN A FAIL SAFE WAY TO PREVENT FAILURE OF THE QUENCH DETECTOR DUE TO FAILURE OF ONE OF ITS COMPONENTS. A METHOD FOR QUICK BALANCING OF THE QUENCH DETECTION SYSTEM IN A LARGE TOROIDAL MAGNET SYSTEM WAS APPLIED. THE SYSTEM WHICH WAS WITHIN THE QUENCH DETECTION LEVEL SETTING OF 50 MILLIVOLTS, WAS NOT SENSITIVE TO POLOIDAL FIELD TRANSIENTS AT OR BELOW THIS LEVEL. NON-ELECTRICAL METHODS FOR QUENCH DETECTION WERE ALSO INVESTIGATED.
Details
- Original title: QUENCH DETECTION SYSTEM OF THE EURATOM COIL FOR THE LARGE COIL TASK (LCT).
- Record ID : 1991-1997
- Languages: English
- Source: Cryogenics - vol. 29 - n. 12
- Publication date: 1989
Links
See other articles in this issue (8)
See the source
Indexing
-
MAGNETIC FIELD MEASUREMENTS WITHIN SUPERCONDUCT...
- Author(s) : JUNGST K. P., KUTSCHERA M., YAN L.
- Date : 1985
- Languages : English
- Source: Cryogenics - vol. 25 - n. 1
View record
-
HALL PROBE FOR MEASURING HIGH CURRENTS IN SUPER...
- Author(s) : FERENDECI A. M.
- Date : 1986
- Languages : English
- Source: Rev. sci. Instrum. - vol. 57 - n. 6
View record
-
NOVEL HALL-EFFECT MEASURING DEVICE FOR USE IN S...
- Author(s) : HEINEMANN K.
- Date : 1985
- Languages : English
- Source: Rev. sci. Instrum. - vol. 56 - n. 1
View record
-
CHARACTERIZATION OF A LARGE SUPERCONDUCTING SPL...
- Author(s) : CROCKETT A. G., KENNEDY T. A.
- Date : 1990
- Languages : English
- Source: Rev. sci. Instrum. - vol. 61 - n. 6
View record
-
MEASUREMENT OF MAGNETIZATION CURVES AND LOSSES ...
- Author(s) : GOMORY F.
- Date : 1986
- Languages : English
- Source: Cryogenics - vol. 26 - n. 5
View record