Regenerator performance with noble gas mixtures.

Author(s) : DANEY D. E.

Type of article: Article

Summary

The performance of regenerators that use noble gas mixtures is compared to the performance of those that use pure helium gas. Both helium-argon and helium-krypton mixtures are investigated. For some heat transfer surfaces, a modest gain in heat transfer can be achieved with these mixtures. The concomitant increase in pressure drop, however, more than offsets the heat transfer gain, so that the net regenerator loss increases for all the cases evaluated.

Details

  • Original title: Regenerator performance with noble gas mixtures.
  • Record ID : 1993-1797
  • Languages: English
  • Source: Cryogenics - vol. 31 - n. 10
  • Publication date: 1991/10

Links


See other articles in this issue (7)
See the source