Screen heat exchanger performance comparison.

Author(s) : LUNA J., RAVIKUMAR K. V., FREDERKING T. H. K.

Type of article: Article

Summary

The performance of stainless steel screen regenerator stacks (500 mesh) has been investigated at relatively small flow rates in comparison to conventional operation close to the laminar-turbulent transition range. A modified "single blow" technique was used initially, and an additional comparative procedure is employed to deduce heat transfer rate ratios with respect to a single-wire reference case of heat transfer. The data obtained are two orders of magnitude below "classical" room temperature values at low Reynolds numbers. The fluid is cold nitrogen from a liquid bath at atmospheric pressure.

Details

  • Original title: Screen heat exchanger performance comparison.
  • Record ID : 1993-1820
  • Languages: English
  • Source: Cryogenics - vol. 32 - n. 2
  • Publication date: 1992

Links


See other articles in this issue (27)
See the source