Simplified optimization method for preliminary design of HVAC system and real building application.
Author(s) : STANESCU M., KAJL S., LAMARCHE L.
Type of article: Article
Summary
HVAC systems (heating, ventilation, and air conditioning) are recognized as the greatest energy consumers in commercial and institutional buildings. Generally, designers use common sense, historical data, and subjective experience in designing these systems; this includes the number of systems chosen and the grouping of the zones served by these systems. HVAC energy efficiency is not an easily calculable criterion during the selection of these systems; usually the first selection criterion is the weakest investment cost. In this article, we present a simplified optimization method for preliminary design of HVAC system using the zones’ daily profile loads. A global load ratio is applied as an optimization function. The global load ratio represents the relationship between the system's real load and its possible maximum load for a given period. The variables for the optimization problem are: (i) grouping of the zones served by the systems and (ii) number of systems serving the building. Type of system was preselected for the present study, but this could also serve as an optimization variable. The correlations between global load ratio and energy consumption were shown using an office building. Then, this method was applied on an existing institutional building and compared with the detailed optimization method. In the second method, the HVAC energy consumption, calculated using DOE-2 software, was used as the optimization function. The comparison made among the existing, reference, and optimized buildings (all sharing the same constraints) have yielded significant energy savings for HVAC energy consumption. A life cycle cost analysis has also been done to estimate savings in terms of investment, operation and maintenance costs. These savings depend upon building configuration, the constraints imposed, the types of HVAC systems selected, and the control strategies for these systems.
Details
- Original title: Simplified optimization method for preliminary design of HVAC system and real building application.
- Record ID : 30008843
- Languages: English
- Source: HVAC&R Research - vol. 19 - n. 3
- Publication date: 2013/04
- DOI: http://dx.doi.org/10.1080/10789669.2012.755904
Links
See other articles in this issue (6)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Building; Ventilation; Design; Optimization; Air conditioning
-
Multi-criteria optimal design of residential ve...
- Author(s) : KIM Y. J., PARK C. S.
- Date : 2009/07/27
- Languages : English
View record
-
INDUCTION UNITS WITH IMPROVED ROOM AIR FLOW.
- Author(s) : ROTH H. W.
- Date : 1989
- Languages : German
- Source: Klima Kälte Heiz. - vol. 17 - n. 11
View record
-
Are intelligent agents the key to optimizing bu...
- Author(s) : KELLY G. E., BUSHBY S. T.
- Date : 2012/08
- Languages : English
- Source: HVAC&R Research - vol. 18 - n. 4
View record
-
Discussion of design method and optimization on...
- Author(s) : HUANG C., WANG X.
- Date : 2009/06/21
- Languages : English
- Source: 2009 ASHRAE Annual Conference CD. Transactions papers presented at the 2009 ASHRAE Annual Conference: Louisville, KY, June 2009. Volume 115, part 2.
View record
-
Designing HVAC systems using particle swarm opt...
- Author(s) : BRAVO R. H., FLOCKER F. W.
- Date : 2012/10
- Languages : English
- Source: HVAC&R Research - vol. 18 - n. 5
View record