Simplifying energy performance assessment in the Hong Kong building environmental assessment method.
Author(s) : LEE W. L., YIK F. W. H., BURNETT J.
Type of article: Article
Summary
In the Hong Kong Building Environmental Assessment Method (HK-BEAM) for air-conditioned office premises, energy use for air-conditioning constitutes one major item of assessment. The current assessment method for existing offices is based on computer simulation predictions. Following a recent review of the HK-BEAM scheme, simplified models have been developed for use in the assessment as an alternative to the detailed simulation method. These models are multiple linear regression models relating the annual electricity use for air-conditioning, and the maximum electricity demand, in an office building to the key characteristics of the building envelope and the air-conditioning system. Use of these models can reduce the effort required for data collection and input, and will allow the assessors to more quickly complete an assessment. In addition, additional parametric studies can be performed within much less time, which will help assessors in formulating advice to developers/designers on measures that will lead to improved energy performance and thus higher credits. This article summarizes the review findings and describes the approach taken in the establishment of the regression models. Comparison of predictions by the detailed computer simulation method and the alternative method showed that the latter could provide estimates close enough to the simulation predictions for the purpose of assessing the credits to be awarded to a building for its energy performance.
Details
- Original title: Simplifying energy performance assessment in the Hong Kong building environmental assessment method.
- Record ID : 2004-2915
- Languages: English
- Subject: Environment
- Source: Build. Serv. Eng. Res. Technol. - vol. 22 - n. 2
- Publication date: 2001/05
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (4)
See the source
Indexing
-
First zero carbon building in Hong Kong.
- Author(s) : LAI A., LEUNG M. K., YAU R., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Measurement and verification for performance co...
- Author(s) : FONG K. F., FONG M. L., CHOW T. T.
- Date : 2009/05/20
- Languages : English
- Source: ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
View record
-
An experience of energy auditing on a central a...
- Author(s) : YIK F. W. H., BURNETT J.
- Date : 1995
- Languages : English
- Source: J. Energy Eng. - vol. 92 - n. 2
View record
-
Rare event analysis of high dimensional buildin...
- Author(s) : FAN C., XIAO F., WANG S.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 3rd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Outdoor design conditions for heating ventilati...
- Author(s) : LAM J. C., HUI S. C. M.
- Date : 1995/03
- Languages : English
- Source: Energy Build. - vol. 22 - n. 1
View record