Static analysis of a new scheme of two stage refrigeration cycle with the combination of FAM Z01 and FAM Z05 adsorbents.
Author(s) : AKISAWA A., UMAIR M., ENOKI K., et al.
Type of article: Article, IJR article
Summary
This paper presents static analyses of two stage adsorption cycle using FAM Z01 and FAM Z05 as the adsorbents. The conventional two stage system consists of four adsorbent beds. In contrast, in new scheme three beds were used assigning FAM Z01 and FAM Z05 combination for low and high pressure sides, respectively. The objectives of this study were to evaluate the performance of two stage cycle with the Z01 and Z05 combination of adsorbent pair, and to compare the performance with that of the conventional two stage cycle using Silica-gel. Static analysis based on Dühring diagram was employed to estimate the performances of specific cooing effect (SCE) and COP. It was found that the cycle with new combination gives SCE more than twice compared with the conventional Silica-gel–water system at the heat source temperature of 55°C. The sensitivity analysis was also performed for optimal mass allocation to adsorbent beds.
Available documents
Format PDF
Pages: 143-153
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Static analysis of a new scheme of two stage refrigeration cycle with the combination of FAM Z01 and FAM Z05 adsorbents.
- Record ID : 30024307
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 92
- Publication date: 2018/08
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2018.04.011
Links
See other articles in this issue (21)
See the source
Indexing
- Themes: Absorption and adsorption systems
- Keywords: Silica gel; Two-stage system; Adsorption system; Simulation; Performance
-
Experimental study on a two-stage adsorption re...
- Author(s) : HAMAMOTO Y., AKISAWA A., HAGA N., et al.
- Date : 2002/09/24
- Languages : English
- Source: Proceedings of the International Sorption Heat Pump Conference.
View record
-
Performance evaluation of a two-stage silica ge...
- Author(s) : MITRA S., KUMAR P., SRINIVASAN K., et al.
- Date : 2015/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 58
- Formats : PDF
View record
-
Performance evaluation of a two-stage adsorptio...
- Author(s) : HAMAMOTO Y., ALAM K. C. A., AKISAWA A., et al.
- Date : 2005/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 3
- Formats : PDF
View record
-
Modeling study of two-stage, multi-bed air cool...
- Author(s) : MITRA S., THU K., SAHA B. B., et al.
- Date : 2017/03/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 114
View record
-
Development and performance studies of an air c...
- Author(s) : MITRA S., KUMAR P., SRINIVASAN K., et al.
- Date : 2016/07
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Formats : PDF
View record