TEMPERATURE VARIATION OF THERMAL CONDUCTIVITY OF SELF-PUMPING MULTILAYER INSULATION.
Author(s) : HALACZEK T. L., RAFALOWICZ J.
Type of article: Article
Summary
TEMPERATURE DEPENDENCE OF THE THERMAL CONDUCTIVITY OF SELF-PUMPING MULTILAYER INSULATION WAS MEASURED IN THE TEMPERATURE RANGE 90-295 K. THE MEASUREMENTS WERE PERFORMED WITH A FLAT-PLATE CALORIMETER AND USING THE INTEGRAL METHOD. A COMPARISON WAS MADE BETWEEN THE THERMAL CONDUCTIVITIES OF THE SELF-PUMPING INSULATION AND THE CONVENTIONAL TYPE.
Details
- Original title: TEMPERATURE VARIATION OF THERMAL CONDUCTIVITY OF SELF-PUMPING MULTILAYER INSULATION.
- Record ID : 1987-0897
- Languages: English
- Source: Cryogenics - vol. 26 - n. 10
- Publication date: 1986
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Thermodynamic measurements
- Keywords: Thermal conductivity; Calorimeter; Measurement; Multilayer insulation; Insulation
-
THERMAL CONDUCTIVITY OF MULTILAYER INSULATIONS ...
- Author(s) : PASTOR L.
- Date : 1983/08/07
- Languages : English
- Source: [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Formats : PDF
View record
-
HEAT TRANSPORT IN SELF-PUMPING MULTILAYER INSUL...
- Author(s) : HALACZEK T. L., RAFALOWICZ J.
- Date : 1986/06
- Languages : English
- Source: Cryogenics - vol. 26 - n. 6
View record
-
STUDY OF HEAT TRANSFER IN MULTILAYER INSULATION...
- Author(s) : MIKHALCHENKO R. S.
- Date : 1983
- Languages : English
- Source: Cryogenics - vol. 23 - n. 6 1983.06
View record
-
SYSTEMATIC STUDY TO REDUCE THE EFFECTS OF CRACK...
- Author(s) : SHU Q. S., FAST R. W., HART H. L.
- Date : 1987
- Languages : English
- Source: Cryogenics - vol. 27 - n. 6
View record
-
MEASUREMENT OF EQUIVALENT THERMAL CONDUCTIVITY ...
- Author(s) : KULKARNI A. A., NARAYANKHEDKAR K. G.
- Date : 1985
- Languages : English
- Source: Indian J. Technol. - vol. 23 - n. 1
View record