The effectiveness method to predict the behaviour of a desiccant wheel: An attempt of experimental validation.
Author(s) : RUIVO C. R., ANGRISANI G.
Type of article: Article
Summary
The desiccant wheel is a key component in solid-desiccant systems. At present, the analysis of the behaviour of air handling units based on desiccant wheels is a complex task. It is difficult to access a simple model that can represent the behaviour of commercialized desiccant wheels with sufficient accuracy. Experimental data measured in an air handling unit equipped with a desiccant wheel are considered in the present work. The air handling unit belongs to a test facility with a microcogeneration system located at Università degli Studi del Sannio (in Benevento, Southern Italy). Thermal energy from the microcogenerator is used to heat up the regeneration airflow. An attempt of investigating the validity of the simplified effectiveness method in predicting the global behaviour of a desiccant wheel is performed. Two approaches are used with different pair of effectiveness parameters. Only one sensor of temperature and one sensor of relative humidity were used in each measuring section of the air handling unit. This constraint is most crucial at both outlet sections of the desiccant wheel due to the strong dependence of the air state on the angular position. An empirical correction of the measured state of the process air at the outlet of the desiccant wheel is used. The corrected data are used in the investigation of the validity of the effectiveness method by using constant values in a large set of cases where the rotation speed of the desiccant wheels and the fans are kept constant. Important deviations between the predicted and the experimental results were found in a significant number of cases, therefore there is the need of improving the method by taking into account the effect on the effectiveness parameters of varying the inlet states of both airflows.
Details
- Original title: The effectiveness method to predict the behaviour of a desiccant wheel: An attempt of experimental validation.
- Record ID : 30013838
- Languages: English
- Source: Applied Thermal Engineering - vol. 71 - n. 2
- Publication date: 2014/10
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.10.028
Links
See other articles in this issue (5)
See the source
Indexing
-
Experimental analysis on the performances of a ...
- Author(s) : ANGRISANI G., MINICHIELLO F., ROSELLI C., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Application of desiccant wheel dehumidifying sy...
- Author(s) : ZHANG Y., DU S., GUAN Y., et al.
- Date : 2014/10
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 295
- Formats : PDF
View record
-
Optimisation of a desiccant cooling system desi...
- Author(s) : GOLDSWORTHY M., WHITE S.
- Date : 2011/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 1
- Formats : PDF
View record
-
Measurements of effectiveness in a silica gel r...
- Author(s) : NETI S., WOLFE E. I.
- Date : 2000/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 20 - n. 4
View record
-
Novel desiccant cooling system using indirect e...
- Author(s) : BELDING W. A., DELMAS M. P. F.
- Date : 1997
- Languages : English
- Source: ASHRAE Transactions.
View record