Summary
A two-stage pulse tube refrigerator in combination with a rotary valve and a valved compressor has been constructed. A minimum temperature of 11.5 K and a cooling capacity of 1.3 watt at 20 K were obtained at a frequency of 4.2 hertz and a system pressure of 1.5 megapascal. The 2nd-stage regenerator was only filled with lead shot.
Details
- Original title: The experimental investigation of a two-stage pulse tube refrigerator.
- Record ID : 1997-1304
- Languages: English
- Source: Cryogenics - vol. 36 - n. 8
- Publication date: 1996/08
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Pulse tube; Thermal power; Cryocooler
-
ETUDE EXPERIMENTALE D'UN REFRIGERATEUR DU TYPE ...
- Author(s) : DOMBLIDES J. P., DALIGAULT J., VEYSSIE J. J.
- Date : 1991/08/10
- Languages : French
- Source: New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
- Formats : PDF
View record
-
Analysis of mass and energy flow rates in an or...
- Author(s) : KURIYAMA F., RADEBAUGH R.
- Date : 1999/01
- Languages : English
- Source: Cryogenics - vol. 39 - n. 1
View record
-
Numerical simulation of the high frequency mini...
- Author(s) : JU Y. L., ZHOU Y.
- Date : 1998/04/21
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR '98.
View record
-
Theoretical studies on the regenerator of a sin...
- Author(s) : BAO D., DANG H., ZHAO Y., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Pulse-tube refrigerator and nitrogen liquefier ...
- Author(s) : KAKIMI Y, ZHU S. W., ISHIGE T., FUJIOKA K., MATSUBARA Y.
- Date : 1996/06/25
- Languages : English
- Source: Cryocoolers 9. Proceedings of the International Cryocooler Conference.
View record