The stress and deflection analysis for the radial blades of the roto-cooler air conditioning system.
Author(s) : HUANG Y. M., CHANG C. H.
Type of article: Article, IJR article
Summary
The governing equations are derived by using the finite element method. The assumptions used in the analysis are that air properties in the blade segments are uniform and the rotor is a rigid body. A computer code is generated for the personal computer to reduce the cost of design. The calculated results of the stress and the deflection of the blades are compared and show good agreement with those obtained by the available software ABAQUS. The distributions of the stress and the deflection of the radial blades for the roto-cooler air conditioning system are analyzed. The locations and the magnitudes of the maximum stresses and the maximum displacement of the blades are determined. The calculated factor of safety of the blades is 11.
Available documents
Format PDF
Pages: 55-62
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The stress and deflection analysis for the radial blades of the roto-cooler air conditioning system.
- Record ID : 1997-2333
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 20 - n. 1
- Publication date: 1997/01
Links
See other articles in this issue (6)
See the source
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Software; Calculation; Design; Simulation; Air conditioning; Rotary compressor; Heat exchanger
-
Cooling performance simulation using the ZEBRA ...
- Author(s) : MARSHALLSAY P. G., LUXTON R. E.
- Date : 1996/02/11
- Languages : English
- Source: Refrigeration, Climate Control and Energy Conservation.
- Formats : PDF
View record
-
Impacts of manufacturing tolerances on the effe...
- Author(s) : SHANG W., BESANT R. W.
- Date : 2006
- Languages : English
- Source: ASHRAE Transactions. 2006 Winter Meeting. Volume 112, part 1 + CD-ROM.
View record
-
CREATING A PROLOG KNOWLEDGE-BASED SYSTEM USING ...
- Author(s) : BERGT C.
- Date : 1989
- Languages : English
View record
-
Analysis of the roto-cooler air-conditioning sy...
- Author(s) : YUAN M. H.
- Date : 1995/07
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 18 - n. 6
- Formats : PDF
View record
-
A steady-state simulation of an advanced desicc...
- Author(s) : CHANT E. E., JETER S. M.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record