Thermal energy storage "Cristopia". Applications in Romania: the air-conditioning system in the supermarket "Crisul Oradea".
Skladistenje topoltne energije "Cristopia". Primena u rumuniji: klimatizacioni sistemi u supermarketu "Crisul Oradea".
Author(s) : DOBOSI I. S., DIACONU I., RETEZAN A., et al.
Type of article: Article
Summary
Thermal energy storage is particularly well adapted to air conditioning and industrial refrigeration systems. By smoothing the production of cooling energy, thermal energy storage (STL) optimizes the use of electrical resources and protects the environment. Traditional air conditioning systems rarely operate at full capacity. They usually operate during the day to meet the building demand and remain idle at night. Chillers are selected to satisfy the maximum instantaneous cooling demand, which occurs only a few days each year. Industrial refrigeration systems provide cooling for a wide variety of application, many of which require high cooling capacities for short periods only (corresponding to the production cycles). The STL is a flexible and reliable solution for the management of these important energy needs. It enables a significant reduction in installed chiller capacity (up to 70), the use of low tariff electricity for significant running cost savings and effective management of cooling according to the real demand.
Details
- Original title: Skladistenje topoltne energije "Cristopia". Primena u rumuniji: klimatizacioni sistemi u supermarketu "Crisul Oradea".
- Record ID : 2006-3101
- Languages: Serbian
- Source: KGH (Klimatizacija Grejanje Hladenje) - vol. 35 - n. 2
- Publication date: 2006/05
Links
See the source
-
Determination of basic design parameters based ...
- Author(s) : LIU Y., LONG X., JIANG X., et al.
- Date : 2010/10
- Languages : Chinese
- Source: HV & AC - vol. 40 - n. 242
- Formats : PDF
View record
-
Cristopia thermal energy storage: applications ...
- Author(s) : DOBOSI I. S., JAY F.
- Date : 2006/11/20
- Languages : English
View record
-
Refrigerating system for convenience stores.
- Author(s) : SEKINE S., TAKEUCHI M., ITOU K.
- Date : 2005
- Languages : Japanese
- Source: Refrigeration - vol. 80 - n. 927
View record
-
Experimental investigation of the temperatures ...
- Author(s) : LĂ“PEZ-NAVARRO A., BIOSCA-TARONGER J., TORREGROSA-JAIME B., et al.
- Date : 2013/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Formats : PDF
View record
-
Energy storage in freezer cabinets using phase ...
- Author(s) : RAEISI A. H., SUAMIR I., TASSOU S. A.
- Date : 2013/04/02
- Languages : English
- Source: 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
View record