Thermal performance of multilayer insulation around a horizontal cylinder.

Author(s) : OHMORI T.

Type of article: Article

Summary

Thermal performance of multiplayer insulation (MLI) is affected by contact pressure between adjacent layers. In order to evaluatethe thermal performance of the MLI fabricated in the horizontal cryostats of superconducting magnets, it is important to investigatethe contact pressure in the MLI. In case of a horizontal cryostat, the MLI is wound around horizontal cylindrical surface and is compressed at the upper part of the cylinder due to the MLI self-weight. At first, a single thin film wound around the horizontal cylinder was analyzed to evaluate the contact pressure acting on the cylinder. The analysis has been extended to the multiply wound film around the horizontal cylinder, in order to investigate the distribution of contact pressure between adjacent layers. By using experimental data obtained with a flat panel calorimeter, the results of this analysis have been applied to evaluate the thermal performance of MLI around a horizontal cylinder. And the non-dimensional contact pressure parameter has been introduced as a useful parameter to evaluate and compare the thermal performance among different kinds of MLI. [Reprinted with permission from Elsevier. Copyright, 2005].

Details

  • Original title: Thermal performance of multilayer insulation around a horizontal cylinder.
  • Record ID : 2006-2759
  • Languages: English
  • Source: Cryogenics - vol. 45 - n. 12
  • Publication date: 2005/12