TRANSITION BOILING MODELS IN HEAT EXCHANGERS.

Author(s) : FRANCE D. M.

Type of article: Article

Summary

A RELATION WAS DEVELOPED FROM EXPERIMENTAL DATA FOR THE PREDICTION OF THE QUALITY CHANGE IN THE TRANSITION BOILING REGION. THIS QUALITY RELATION WAS USED ALONE AND IN CONJUNCTION WITH A TRANSITION BOILING HEAT TRANSFER COEFFICIENT TO FORMULATE 2 SUCCESSFUL MODELS. PREDICTIONS OF HEAT EXCHANGER HEAT TRANSFER, INCLUDING THE TRANSITION BOILING MODELS, WERE COMPARED WITH EXPERIMENTAL RESULTS FOR HIGH-PRESSURE WATER IN THE RANGE 7-15.3 MEGAPASCALS OVER A MASS FLUX OF 0.7-3.2 TONNES/M2.SEC.

Details

  • Original title: TRANSITION BOILING MODELS IN HEAT EXCHANGERS.
  • Record ID : 1989-0887
  • Languages: English
  • Source: J. Heat Transf. - vol. 110 - n. 3
  • Publication date: 1988
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (5)
See the source