Vote method of deciding supply air temperature set point for a variable-air-volume (VAV) air-conditioning system.
Author(s) : CHEN X., KAMIMURA K.
Summary
This collection of 107 papers presented at the ASHRAE 2001 Winter Meeting, held in Atlanta, Georgia, January 27-31, include the complete collection of symposium and technical papers as well as discussion questions and answers for every paper. Topics: case studies and modeling for heating systems with special emphasis on radiant panel systems; central energy plant kW per ton and demand controls; innovative materials and building envelope systems; absorption/sorption heat pumps and refrigeration systems; analysis tools for the design of low energy cooling systems; thermal-energy storage systems aging gracefully; integration of dedicated outside air dehumidification systems and terminal sensible cooling/heating; pumping design and performance modeling of geothermal heat pump systems; thermoeconomics and second law analysis of HVAC&R systems; characterizing the performance of non-simple fenestrations; smoke management research and case studies of large spaces; effects of international building code 2000 on seismic design for HVAC; modelling and measurement of VOC emissions from building materials; recent results from fault detection and diagnostic research; combustion turbine inlet cooling; advances in thermal and fluid flow characteristics of HVAC and refrigeration processes.
Details
- Original title: Vote method of deciding supply air temperature set point for a variable-air-volume (VAV) air-conditioning system.
- Record ID : 2002-0939
- Languages: English
- Source: ASHRAE Transactions. 2001 Winter Meeting, Atlanta, GA. Volume 107, part 1 + CD-ROM.
- Publication date: 2001
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (60)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Variable volume; Air change; Air; Process; Optimization; Air conditioning
-
Minimum ventilation control for variable air vo...
- Author(s) : KETTLER J. P.
- Date : 1995/06/24
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Simulation results and analysis of eight ventil...
- Author(s) : KE Y. P., MUMMA S. A., STANKE D.
- Date : 1997
- Languages : English
- Source: ASHRAE Transactions.1997 Annual Meeting, Boston, MA.
View record
-
A study of MFVAV system. 2. Outdoor air flow co...
- Author(s) : CHEN Y., YIN P.
- Date : 1997/09/09
- Languages : English
- Source: International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
View record
-
Minimum outside air control methods for variabl...
- Author(s) : ELOVITZ D. M.
- Date : 1995/06/24
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Airflow sensing: toward providing indoor air qu...
- Author(s) : SAUER H. J., GEORGE R., UTTERSON E. G.
- Date : 1996/10
- Languages : English
View record