Résumé
This study focused on a vertical open-type display cabinet with double air curtain, and investigated the effect of pre-cooler on
supply and return air of air curtain in display cabinet. The experimental investigation was undertaken in the test room with temperature of 25°C and relative humidity of 60%. The results showed that: the temperature of the supply air was not obviously elevated, and the return air temperature was reduced by 5°C ; the inner supply air and the return air relative humidity of air curtain changed little, the outer supply air relative humidity dropped from 69% to 60% ; and the enthalpy of outer supply air kept a fixed value, and the enthalpy of the return air decreased by 21.4%. The decreases of return air temperature and enthalpy could lead to significant decrease in the display cabinet load.
Documents disponibles
Format PDF
Pages : 111-114
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30011255
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 35 - n. 156
- Date d'édition : 04/2014
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2014.02.111
Liens
Voir d'autres articles du même numéro (13)
Voir la source
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Air repris; Pré-refroidissement; Meuble de vente; Température; Rideau d'air; Experimentation
-
Effet du prérefroidisseur sur des rideaux d'air...
- Auteurs : YANG X., ZHANG W., GONG Y.
- Date : 09/2007
- Langues : Chinois
- Source : Refrigeration - vol. 26 - n. 3
Voir la fiche
-
Etudes expérimentales sur l'impact des caractér...
- Auteurs : CHEN T., LI Y., YU K., et al.
- Date : 2004
- Langues : Chinois
- Source : Journal of Refrigeration - n. 3
- Formats : PDF
Voir la fiche
-
Etudes expérimentales sur la performance thermi...
- Auteurs : CHEN T. J., LI Y. H., YU K. Z., et al.
- Date : 2004
- Langues : Chinois
- Source : Refrigeration - vol. 87 - n. 2
Voir la fiche
-
Performance comparison between shorter and conv...
- Auteurs : PITCHERS S., MARQUES C., REES R., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Investigation of energy-efficient supermarket d...
- Auteurs : WALKER D. H., FARAMARZI R. T., BAXTER V. D.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche