A DEFROSTING CONTROLLER FOR ENERGY SAVING IN HEAT PUMP ROOM AIR CONDITIONERS.

[In Japanese. / En japonais.]

Author(s) : IWATA H., SAKAZUME A., TAKEBAYASHI M.

Type of article: Article

Summary

THIS PAPER IS TO REPORT A DEFROST CONTROL DEVICE FOR ENERGY SAVING IN HEAT PUMP ROOM AIR CONDITIONERS. THE PROBLEMS OF DEFROST CONTROL ARE NOT ONLY TO DETECT FROST BUT ALSO TO JUDGE A TIMING TO START DEFROSTING DURING FROST FORMATION. TO CLARIFY THE CRITERION OF DEFROSTING, A JUDGEMENT FOR ENERGY SAVING WAS ATTEMPTED. NAMELY, THE AUTHORS PROPOSED AS A CRITERION THAT DEFROSTING IS STARTED WHEN THE INTEGRATED MEAN HEATING CAPACITY REACH A MAXIMUM. MOREOVER, A METHOD INDICATING THAT THE FROST CONDITION REACHES THE CRITERION OF DEFROST STARTING WAS STUDIED, AND HEATING CHARACTERISTICS WERE COMPARED WITH USUAL DEFROST CONTROL.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 1986-1921
  • Languages: Japanese
  • Source: Refrigeration - vol. 60 - n. 691
  • Publication date: 1985
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (4)
See the source