A MODEL TO COMPARE FREEZING CONTROL STRATEGIES FOR RESIDENTIAL AIR-TO-AIR HEAT RECOVERY VENTILATORS (HRVS).
Author(s) : PHILLIPS E. G.
Summary
A COMPUTER PROGRAM WAS DEVELOPEDTO SIMULATE THE PERFORMANCE OF RESIDENTIAL AIR-TO-AIR HRVS OF VARIOUS EFFECTIVENESSES OPERATING UNDER FROSTING CONDITIONS. ALGORITHMS WERE DEVELOPED TO PREDICT THE ENERGY PERFORMANCE OF THE HRVS FOR SEVERAL FROST CONTROL AND DEFROST STRATEGIES FOR ANY PRESCRIBED CLIMATIC CONDITIONS. THE PAPER DESCRIBES THE WEATHER MODEL, THE HEAT EXCHANGER PERFORMANCE/FROSTING MODEL, AND THE DEFROST AND FROST CONTROL ALGORITHMS.
Details
- Original title: A MODEL TO COMPARE FREEZING CONTROL STRATEGIES FOR RESIDENTIAL AIR-TO-AIR HEAT RECOVERY VENTILATORS (HRVS).
- Record ID : 1991-0819
- Languages: English
- Publication date: 1989
- Source: Source: ASHRAE Trans.
vol. 95; n. 2; 475-483; 11 fig.; 16 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
-
COMPARISON OF FREEZING CONTROL STRATEGIES FOR R...
- Author(s) : PHILLIPS E. G.
- Date : 1989
- Languages : English
View record
-
NEW DEFROSTING SYSTEM FOR RESIDENTIAL HEAT PUMPS.
- Author(s) : MUROZONO K., WAKABAYASHI H., HORI M.
- Date : 1986/08/05
- Languages : English
- Source: Progress in the design and construction of refrigeration systems.
- Formats : PDF
View record
-
FIELD-MEASURED CYCLING, FROSTING AND DEFROSTING...
- Author(s) : BAXTER V. D., MOYERS J. C.
- Date : 1985
- Languages : English
View record
-
EFFECT OF RESIDENTIAL AIR-TO-AIR HEAT AND MOIST...
- Author(s) : BARRINGER C. G., MCGUGAN C. A.
- Date : 1989
- Languages : English
View record
-
ADVANCES IN HEAT PUMP MODULATION.
- Author(s) : WILSON R. D.
- Date : 1990/03/12
- Languages : English