Summary
A small coil, wound with a multifilamentary niobium-aluminium conductor, was tested over the temperature range 4.2-12 K. The experiment not only encompassed measurements of the conductor's critical currents but also the coil's performance, e.g. 4.8 T (180 A) at 4.2 K and 3.2 T (120 A) at 12 K, and the winding's turn-to-turn normal-zone propagation velocities. The coil's stable performance of 120 A at 12 K nearly matched the conductor's short-sample critical current.
Details
- Original title: A niobium-aluminium coil: performance, including quench behaviour, in the temperature range 4.2-12 K.
- Record ID : 1997-1335
- Languages: English
- Source: Cryogenics - vol. 36 - n. 9
- Publication date: 1996/09
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Superconduction
- Keywords: Superconduction; Superconducting coil; Aluminium; Superconductor; Stability; Performance; Niobium; Critical current
-
Voltage-current characteristics of multifilamen...
- Author(s) : BOSCHMAN H., KATE H. H. J. ten, KLUNDERT L. J. M. van de
- Date : 1990/09
- Languages : English
- Source: Cryogenics - vol. 30
View record
-
Stability tests on R&D superconductors for the ...
- Author(s) : MITO T., YAMAMOTO J., TAKAHATA K., et al.
- Date : 1991/07
- Languages : English
- Source: Cryogenics - vol. 31 - n. 7
View record
-
STABILITY TESTS ON THE EURATOM LARGE COIL TASK ...
- Author(s) : SCHMIDT C.
- Date : 1984
- Languages : English
- Source: Cryogenics - vol. 24 - n. 11
View record
-
Electro- and thermophysical characteristics of ...
- Author(s) : CHERNAVSKY Ju. P., MALKOVSKY V. I., SKOBARIKHIN Ju. V.
- Date : 1992
- Languages : English
- Source: Cryogenics - vol. 32 - n. 3
View record
-
Fabrication and evaluation of small coils using...
- Author(s) : KUBO Y., UCHIKAWA F., UTSUNOMIYA S., NOTO K., KATAGIRI K., KOBAYASHI N.
- Date : 1993/09
- Languages : English
- Source: Cryogenics - vol. 33 - n. 9
View record